SMS alarm Temperature logger (wireless monitoring)

  • SMS alarm Temperature  logger (wireless monitoring)
  • SMS alarm Temperature  logger (wireless monitoring)
  • SMS alarm Temperature  logger (wireless monitoring)
  • SMS alarm Temperature  logger (wireless monitoring)
  • SMS alarm Temperature  logger (wireless monitoring)
Model No.︰ZDR-11y
Brand Name︰jingying
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
Share on:

 Total 12 Related Items 
Prev45678Next

Product Description
I. Introduction
Recorder SMS telemetry, alarm device is a matching with the recorder, cell phone text message real-time remote query data recorder and automatically accept the recorder alarm equipment. An instrument more than one recorder can be connected.
GSM mobile phone network developed through the years, and now has a very mature, less blind spots, signal stability, automatic roaming, and the communication distance from the surrounding environmental impact. In particular the GSM short message, flexible and convenient, you can cross-market, inter-provincial and even cross-border transmission, and each send a short message as long as a dime, very reliable and cheap. Therefore, to achieve the alarm using a mobile phone text messages, ultra long-range telemetry data recorder is a very good choice.
Second, functional
l query specified using a mobile phone real-time data logger, temperature and humidity conditions at any time control of the scene.
l recorder mobile phone to receive alarm signals, timely processing of emergency.
l cell phone alarm set to the specified upper and lower limits recorder data.
l using a mobile phone turned on or off the designated recorder alarm.
Widely used in cold storage, cold chain monitoring, food, vaccines, transportation and other fields, can greatly improve management effectiveness.
Third, the installation method
1, no need to purchase a monthly fee of GSM mobile phone network card (with no SIM card), both China Mobile and Unicom. The SIM card into the SMS telemetry, alarm devices.
2, the recorder and SMS telemetry, alarms Used for communication cable connected.
3, connected to SMS telemetry, alarm device power supply can be used.
Select SIM card note the following:
1, only network with a GSM mobile phone cards, CDMA card can not be used.
2, mobile phone Caller ID card should be opened, otherwise some features can not be achieved.
3, phone cards can not set the boot password, or GSM network can not log in successfully.
4 this phone card to guarantee a certain fund balance to cover the costs incurred when sending messages.
5, mobile phone cards in use, before the phone is set up into the short message service center number. Short message service center number is different for each place, the specific can ask the local 10086 or 10010.
The use of methods
SMS alarm communication device and recorder notes:
1. SMS telemetry, alarm devices installed on the SIM card, connected to the 12V power supply, the power indicator light red light has been the second light starts flashing, blinking, when the light of 600 ms, off 600 ms, that is landing network; bright 75 ms, off for 3 seconds, the network said it had landed. The third indicator light, text messages began to initialize module will clear the SIM card, the stored message, wait about 25 seconds. Initialization is complete, the buzzer sounds for the third light off before the normal send and receive text messages.
2. Load and remove the SIM card must be powered off when
3. In communication with the computer and recorder, the best to excessive alarm is turned off, or they may interfere with data communications.
  
(1) for inquiries channel data
1. Check the temperature data, edit the message: "wd" or "WD" sent to the SMS telemetry, alarm device number.
(2) open-channel alarm
Open is successful, will receive "open succeeded!" Prompt text.
 
(3) Close the alarm
     
(4) set the upper and lower channel data alarm
Command format: 000SCHxSyxxxSyxxx where y, x to be variable.
Where CHx to channel CH1 that the temperature of the system 1, CH2, said temperature 2.
  
1. Set the alarm temperature a lower and upper limits: upper limit in the former, lower in the post:
  
Command format: 000SCH1SyxxxSyxxx (integer format), set the alarm for the temperature of an upper limit and lower limit, while the temperature an alarm set to open.
  
2. To set the upper limit alarm temperature 2: up front, lower in the post:
  
Command format: 000SCH2SyxxxSyxxx (integer format), set the alarm for the temperature of the upper limit of 2 and the lower limit, while the temperature 2 to open alarm settings.
  
(5) set to receive alarm SMS mobile phone number, you can set up three mobile phone number.
2, set to receive alarm SMS phone number
Through the recorder supporting PC, software settings (see PC, software instructions), each logger can be set up to three phone numbers.

Contact: Li Changjun 13858128602
Official Website: http://www.zdyq.net.cn
Payment Terms︰Bank wire transfer
Product Image






Related Products
Four over-limit alarm logger
Four over-limit alarm logger
Four Temperature Recorder
Four Temperature Recorder
Three-way over-limit alarm logger
Three-way over-limit alarm logger
3 channel temperature recorder
3 channel temperature recorder




Home  |  Product Catalog  |  Custom Page  |  Custom Page  |  Custom Page  |  News  |  Document  |  Contact Us  |  Sitemap  |  Mobile Version
  简体版     繁體版     English
浙ICP备10035796号

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !

HomeContact UsSitemap